Quickly find the product you need
YX-60 Automated Digestion System efficiently provides a series of needed pre-treatment progress for inorganic analysis, such as sample dispensing, heating, shaking, volume determine, sample adding, etc. With huge software storage capacity, the YX-60 motion program can be set automatically to control the digestion time, temperature, heating speed, cooling system, sample adding, etc. Completely replaces the manual sample preparation steps involved in metal digestions.
Widely applied in laboratory pre-treatment for enviroment analysis, food test, quality control, metallurge & mineral. For example, it can be used in heavy metal digestion for soil.
Technical Parameters of Automated Digestion System |
|||
Model No. |
YX-60 |
YX-30 |
YX-60-2 |
Vessels (Samples Capacity) |
60pcs * 50ml |
30pcs * 50ml |
60pcs * 50ml |
Heating material |
Teflon coated graphite |
Teflon coated graphite |
Teflon coated graphite |
Test tube racks |
4pcs (15pcs tubes per rack) |
2pcs (15pcs tubes per rack) |
3pcs (20pcs tubes per rack) |
Digestion eyes diameter |
32.5mm |
32.5mm |
32.5mm |
Holes Temp Difference |
≤0.1℃ |
≤0.1℃ |
≤0.1℃ |
Solvent Channel |
9pcs |
9pcs |
9pcs |
Delivery channel adding accuracy |
<0.5ml OR 1% |
<0.5ml OR 1% |
<0.5ml OR 1% |
Delivery channel adding speed |
> 2ml/s, speed adjustable |
> 2ml/s, speed adjustable |
> 2ml/s, speed adjustable |
Volume determine accuracy |
Better than 1% (50ml) |
Better than 1% (50ml) |
Better than 1% (50ml) |
Temp control |
Ambient ~ 230℃, Intelligent 5 steps heating. |
Ambient ~ 230℃, Intelligent 5 steps heating. |
Ambient ~ 230℃, Intelligent 5 steps heating. |
Temp control accuracy |
≤0.1℃ |
≤0.1℃ |
≤0.1℃ |
Dimension |
445*800*495mm |
445*800*495mm |
445*800*495mm |
Interface port |
RS-232 or USB or WiFi |
RS-232 or USB or WiFi |
RS-232 or USB or WiFi |
Voltage |
AC200-240V/50Hz |
AC200-240V/50Hz |
AC200-240V/50Hz |
Power supply |
15A |
15A |
15A |
YX-60 Automated Digestion Advantages
1. High performance. (Graphite Heating Element)
1> High temperatuer: Ambienet ~230℃
2> Precise heat: ±0.1℃ accuracy
3> Stable heat. Single hole temp flotation: ±1.0℃ at 100℃, 6h
4> Equal heat. Multi holes temp difference: ≤±1.5℃
5> Strong acid/alkalic resistant.
2. Efficient. (Absolutely Automated System)
1> Auto sample delivery.
2> Auto sample cooling & shaking.
3> Auto sample volume determine.
4> Auto temperature/time control.
5> For varies test with software control.
3. Away from Acid Corrosion
1> Teflon coated graphite heating element.
2> Acid/alkalic resistant 50ml teflon test tubes.
3> Sealed safety cover teflon coated exhaust hood.
4. Matched with teflon sample vial. < Strong acid/alkalic resistant>
5. Matched with laptop for software control. <Program automated set available>